Article Text

Download PDFPDF

Intraoperative REBOA: an analysis of the American Association for the Surgery of Trauma AORTA registry
  1. Michael A Vella1,
  2. Ryan Peter Dumas1,2,
  3. Joseph DuBose3,
  4. Jonathan Morrison3,
  5. Thomas Scalea3,
  6. Laura Moore4,
  7. Jeanette Podbielski4,
  8. Kenji Inaba5,
  9. Alice Piccinini5,
  10. David S Kauvar6,
  11. Valorie L Baggenstoss6,
  12. Chance Spalding7,
  13. Charles Fox8,
  14. Ernest E Moore8,
  15. Jeremy W Cannon1,9
  16. The AAST AORTA Study Group
    1. 1Division of Traumatology, Surgical Critical Care and Emergency Surgery, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania, USA
    2. 2Division of General and Acute Care Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA
    3. 3R Adams Cowley Shock Trauma Center, University of Maryland Medical Center, Baltimore, Maryland, USA
    4. 4Division of Trauma and Surgical Critical Care, University of Texas, Houston, Texas, USA
    5. 5Division of Surgical Critical Care and Trauma, Los Angeles County + University of Southern California Hospital, Los Angeles, California, USA
    6. 6Division of Trauma and Surgical Critical Care, San Antonio Military Medical Center/US Army Institute of Surgical Research, San Antonio, Texas, USA
    7. 7Department of Surgery, Grant Medical Center, Columbus, Ohio, USA
    8. 8Department of Surgery, Denver Health Medical Center, Denver, Colorado, USA
    9. 9Department of Surgery, Uniformed Services University of the Health Sciences, Bethesda, Maryland, USA
    1. Correspondence to Dr Michael A Vella, University of Rochester School of Medicine and Dentistry, 601 Elmwood Avenue, Box SURG, Rochester, NY 14642, USA; mavella2{at}gmail.com

    Abstract

    Background Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a less-invasive technique for aortic occlusion (AO). Commonly performed in the emergency department (ED), the role of intraoperative placement is less defined. We hypothesized that operating room (OR) placement is associated with increased in-hospital mortality.

    Methods The American Association for the Surgery of Trauma AORTA registry was used to identify patients undergoing REBOA. Injury characteristics and outcomes data were compared between OR and ED groups. The primary outcome was in-hospital mortality; secondary outcomes included total AO time, transfusion requirements, and acute kidney injury.

    Results Location and timing of catheter insertion were available for 305 of 321 (95%) subjects. 58 patients underwent REBOA in the OR (19%). There were no differences with respect to sex, admission lactate, and Injury Severity Score. The OR group was younger (33 years vs. 41 years, p=0.01) and with more penetrating injuries (36% vs. 15%, p<0.001). There were significant differences with respect to admission physiology. Time from admission to AO was longer in the OR group (75 minutes vs. 23 minutes, p<0.001) as was time to definitive hemostasis (116 minutes vs. 79 minutes, p=0.01). Unadjusted mortality was lower in the OR group (36.2% vs. 68.8%, p<0.001). There were no differences in secondary outcomes. After controlling for covariates, there was no association between insertion location and in-hospital mortality (OR 1.8, 95% CI 0.30 to 11.50).

    Discussion OR REBOA placement is common and generally employed in patients with more stable admission physiology. OR placement was not associated with increased in-hospital mortality despite longer times to AO and definite hemostasis when compared with catheters placed in the ED.

    Level of evidence IV; therapeutic/care management.

    • resuscitation for Shock
    • hemorrhagic shock
    • emergency department thoracotomy
    • endovascular procedures

    This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/.

    Statistics from Altmetric.com

    Request Permissions

    If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

    Background

    Hemorrhage remains the most common cause of preventable death in trauma patients and the second most common cause of all trauma-related deaths.1 2 In this population, non-compressible torso hemorrhage accounts for 60% to 70% of deaths3 4 due to severe hemorrhage from major vessels or solid organs in the chest, abdomen, or pelvis.4 Rapid hemorrhage control is essential in these situations,5 as delayed control is associated with increased mortality.6 7

    In select patients with non-compressible torso hemorrhage, resuscitative endovascular balloon occlusion of the aorta (REBOA) can be used as a bridge to definitive hemostasis.8–12 This approach affords temporary occlusion of the thoracic or infrarenal aorta with a balloon catheter inserted through the common femoral artery.13 14 As such, it represents a rapid, less-invasive alternative to open aortic occlusion (AO).

    Because the median time to death from severe hemorrhage is approximately 1 hour,15 there is now appropriate emphasis on shortening the time to hemostasis as much as possible.5 Currently, the majority of REBOA catheters are placed either in the emergency department (ED) or the operating room (OR).16 ED placement may afford more rapid time to temporary hemostasis or potentially delay definitive hemostasis if placed unnecessarily. Placement in the OR may delay temporary hemostasis, leading to increased mortality. As such, the benefits of ED REBOA insertion as compared with perioperative insertion in the OR have not been explored. We sought to characterize the use of intraoperative REBOA and hypothesized that insertion in the OR is associated with increased in-hospital mortality.

    Methods

    The American Association for the Surgery of Trauma (AAST) AORTA registry prospectively identifies trauma patients undergoing open and endovascular AO at 29 centers. Using the AORTA registry, we performed a retrospective review of all patients who underwent endovascular occlusion of the aorta from January 2013 to December 2017. Collected variables included demographic information, mechanism of injury, blood transfusion requirements, admission physiology, time to successful AO, duration of occlusion, time to definitive hemorrhage control, and location of occlusion. Our primary endpoint was in-hospital mortality, and secondary outcomes included total AO time, transfusion requirements, and development of acute kidney injury.

    A univariate analysis for non-parametric continuous variables was analyzed for skewness using the Shapiro-Wilk test of normality. Values <0.05 were considered skewed and were represented as medians and IQRs. Mann-Whitney U test was used to compare medians between groups, and Student’s t-test was used for normally distributed data. Categorical values were represented as n (%). A χ2 analysis was performed to compare categorical values. Statistical significance was set at p<0.05.

    To investigate the relationships between REBOA occlusion location (OR vs. ED) and in-hospital mortality, we first performed univariate regression between candidate variables and inpatient mortality. Each candidate variable with p<0.2 was then used in a multivariable regression model on the outcome of in-hospital mortality. To adhere to the principle of parsimony and avoid overfitting, we removed variables from the final multivariable model that did not contribute to model discrimination. To assess the adequacy of our sample size, we performed a post-hoc CI analysis with the minimal clinically important difference in mortality set at 10%.17 Stata V.14.2 was used for all statistical analyses.

    Results

    Endovascular AO was performed on 321 patients during the study period. Data on the location and timing of insertion were available for 305 (95%) patients. Fifty-eight (19%) patients underwent REBOA in the OR compared with 247 (81%) in the ED. Thirty-six (64%) catheters were placed in aortic zone I in the OR versus 164 (69%) placed in zone I in the ED (p=0.60). There were no differences between groups with respect to sex, admission lactate, and Injury Severity Score (ISS). However, patients who underwent REBOA in the OR were younger (33 years vs. 41 years, p=0.01) and were more likely to have a penetrating mechanism (36% vs. 15%, p<0.001). There were significant differences with respect to admission physiology; patients in the OR group were more likely to present with higher admission systolic blood pressure (SBP) (110 mm Hg vs. 80 mm Hg, p<0.001), Glasgow Coma Scale (GCS) score (7 vs. 3, p<0.001), and heart rate (HR) (114 vs. 101 beats per minute, p=0.04). Patients in the OR group were less likely to have cardiopulmonary resuscitation (CPR) in progress at admission (3.4% vs. 32.5%, p<0.001). Time from admission to AO was longer in the OR group (75 minutes vs. 23 minutes, p<0.001) as was time to definitive hemorrhage control (116 minutes vs. 79 minutes, p=0.01) (table 1).

    Table 1

    Characteristics of patients undergoing OR vs. ED REBOA placement

    Unadjusted in-hospital mortality was lower in the OR group (36.2% vs. 68.8%, p<0.001), but there were no differences in transfusion requirements or acute kidney injury. Total AO time was also similar between the OR and ED groups (33 minutes vs. 30 minutes, p=0.61). On univariate analysis, time to AO, admission SBP, GCS score, HR, ISS, age, lactate, CPR at admission, and location of REBOA insertion were all associated with the outcome of in-hospital mortality (table 2) and were included in a multivariate logistic regression model.

    Table 2

    Univariate analysis on the outcome of in-hospital mortality

    After controlling for these covariates, there was no independent association between insertion location and in-hospital mortality (OR 1.8, 95% CI 0.30 to 11.50) (table 3).

    Table 3

    Multivariate logistic regression analysis on the outcome of in-hospital mortality

    When time to definitive hemorrhage control was added to the model, the number of observations decreased by 30% (106 to 74). In this smaller model, there was again no association between REBOA insertion location (ED vs. OR) and in-hospital mortality, and time to definitive hemorrhage control was not associated with in-hospital mortality when controlling for the other covariates (online supplementary file 1).

    Supplemental material

    CI analysis demonstrated that a larger sample size would not have identified any clinically significant increase in mortality with OR placement (online supplementary file 2).

    Supplemental material

    Discussion

    In this analysis of the AORTA registry, we examined the use of intraoperative REBOA and characterized the relationship between REBOA placement location and mortality. We found that REBOA placement in the OR was not associated with increased in-hospital mortality in similarly injured patients. Interestingly, the total AO time was similar between the ED and OR groups despite longer time to definitive hemorrhage control in the OR group, and there was no difference in acute kidney injury as a marker of end-organ malperfusion.

    Our study is the first to specifically characterize the use of OR REBOA and compare outcomes between ER and OR REBOA placement. Almost 20% of REBOA catheters in this analysis of the registry were placed in the OR, compared with 26% of catheters in a 2016 study using the same registry.16 Similar to this analysis, using the Aortic Balloon Occlusion Trauma Registry, which identifies REBOA patients from 13 hospitals and six countries across the world, Sadeghi et al18 found that 16% of catheters were placed in the OR and an additional 16% were placed in a hybrid-type setting.

    REBOA use outside of the ED for non-trauma indications has been described.19–22 Studies that have evaluated the use of REBOA in non-trauma and combined trauma/non-trauma settings have noted a higher OR placement rate.9 23 In one study with a total of 11 patients undergoing REBOA placement, most commonly for ruptured visceral aneurysms and massive upper gastrointestinal bleeding, 82% of devices were placed in the OR.23 The authors of that study found OR placement particularly helpful in patients with “hostile” abdomens.

    The importance of rapid hemorrhage control has been well established in the trauma literature. Mortality in hypotensive trauma patients remains high and occurs early after presentation. Harvin et al24 found that hypotensive trauma patients requiring emergent laparotomy (within 90 minutes of admission) had a 46% mortality; 65% of those deaths were related to hemorrhage. In another study looking at trauma deaths within 4 hours of admission, 50% of patients died within the first hour.15 In our study, OR placement was associated with longer time to AO (75 minutes vs. 23 minutes), although location of placement and time to AO were not associated with increased in-hospital mortality after controlling for admission physiology and GCS score. This is in contrast to earlier studies that have shown an association between increased time to hemorrhage control and mortality. Meizoso et al6 found that patients with hypotension with torso gunshot wounds, the majority of which were abdominal, had higher mortality if they arrived in the OR after 10 minutes; cumulative 50% mortality was at 16 minutes. Clarke et al7 found that hypotensive trauma patients with abdominal injuries requiring laparotomy had a 1% increase in the probability of death for every 3 minutes spent in the ED. Prolonged prehospital transfer times have also been associated with increased mortality in patients with torso injuries.25 Our results could differ from those above because patients in the OR group were not hypotensive on arrival, although we attempted to control for this in our regression analysis. It is apparent that REBOA may be used according to patient physiology regardless of location.

    None of the aforementioned studies included patients who underwent REBOA, and the effects of early temporary control with balloon occlusion on outcomes prior to definitive operative intervention are less clear. Placement of REBOA catheters can take time, with one study showing a median time from procedure start to zone I occlusion of 474 seconds (7.9 minutes), compared with 317 seconds (5.3 minutes) for open AO.26 Other studies have shown shorter open procedural times of <4 minutes.27 Although the clinical significance of this time delay is unclear, any benefits of early temporary hemorrhage control with REBOA must be weighed against potential delays in definitive operative intervention especially if the REBOA procedure is challenging and/or unsuccessful. This may be particularly true of patients not truly in extremis.28 One study has shown an association between longer times to the arterial access phase of REBOA placement and mortality.29 Our results showed that time to definitive hemorrhage control was longer in patients who underwent OR placement, probably because these patients were stable in the ED. It can be assumed that catheter placement would not delay definitive control if placed during induction of anesthesia or even during the incision. Perhaps REBOA should be placed in the ED for “non-responders” but can be reserved for the OR in those with ongoing torso hemorrhage who initially respond to resuscitation measures.

    Duration of AO may be another factor that differs between location of REBOA placement. Increased time of balloon occlusion has been associated with increased inflammatory mediators, lactate levels, renal dysfunction, and liver necrosis in animal models.30 31 Saito et al32 showed that the mean duration of AO was shorter in survivors after REBOA placement (21 minutes vs. 35 minutes), although there are many possible explanations for this finding. In our study, the total time of occlusion was similar in the ED and OR groups. This is a surprising finding, as one would expect longer occlusion times for balloons deployed in the ED. One possible explanation is that clinicians are too aggressive in placing catheters in the ED in patients who may not actually require the procedure or may be placing catheters prophylactically without initial inflation of the balloon. In general, it is recommended that zone I occlusion not be performed if time to operative intervention is likely to exceed 15 minutes.33 We did not find a difference between groups with respect to acute kidney injury, a surrogate of end-organ malperfusion during AO.

    We acknowledge the limitations of this study. Although the AAST AORTA registry prospectively captures patients undergoing REBOA placement, data are retrospectively entered into the database and suffer from inherent limitations regarding missing data and time accuracy. In addition, there are factors that influence the decision to perform REBOA and placement location that are not captured in the registry, such as rapid changes in clinical condition, exact indications for placement (ie, transient responder vs. non-responder), provider judgment and experience, initial physiology and injury pattern, and availability of ORs or interventional suites. Full capture of the physiologic response to resuscitation or further decompensation is beyond the scope of the database. Differences in the outcomes related to location of REBOA placement could suffer from selection or survival bias. We attempted to mitigate some of this bias by controlling for the effects of admission physiology and GCS score in our logistic regression model.

    Conclusions

    Placement of REBOA catheters in the OR is relatively common and does not appear to be associated with increased in-hospital mortality despite longer times to AO and definite hemostasis when compared with catheters placed in the ED. These findings could be related to the complex interplay between time to temporary versus definitive hemorrhage control. Future studies are needed to further elucidate the timeframe in which REBOA is most effective.

    References

    Footnotes

    • Presented at These data were presented in poster format at the 77th Annual Meeting of the American Association for the Surgery of Trauma, September 26–29, 2018 in San Diego, California.

    • Collaborators AAST AORTA Study Group: Jonny Morrison, MD, PhD; Thomas M. Scalea, MD University of Maryland / R Adams Cowley Shock Trauma Center Baltimore, MD, USA Laura J. Moore, MD, FACS; Jeanette M Podbielski, RN, CCRP; John B. Holcomb, MD; University of Texas Health Sciences Center– Houston Houston, TX, USA Kenji Inaba, MD; Alice Piccinini, MD Los Angeles County + University of Southern California Hospital Los Angeles, CA, USA David S. Kauvar, MD, FACS; Valorie L. Baggenstoss, MSN, RN; Catherine Rauschendorfer BSN, RN San Antonio Military Medical Center / US Army Institute of Surgical Research San Antonio, TX, USA Jeremey Cannon, MD; Mark Seamon, MD; Ryan Dumas, MD; Michael Vella, MD; Jessica Guzman University of Pennsylvania Philadelphia, PA, USA Chance Spalding, DO, PhD; Timothy W. Wolff, DO Ohio Health Columbus, Ohio, USA Chuck Fox, MD; Ernest Moore, MD Denver Health and Hospital Authority Denver, CO USA David Turay, MD; Cassra N. Arbabi, MD; Xian Luo-Owen, PhD Loma Linda University Medical Center Loma Linda, CA, USA David Skarupa, MD; Jennifer A. Mull, RN, CCRC; Joannis Baez Gonzalez University of Florida – Jacksonville Jacksonville, FL, USA Joseph Ibrahim, MD; Karen Safcsak RN, BSN Orlando Regional Medical Center Orlando, FL, USA Stephanie Gordy, MD; Michael Long, MD Ben Taub General Hospital / Baylor College of Medicine Houston, TX, USA Andrew W. Kirkpatrick, MD; Chad G. Ball, MD; Zhengwen Xiao, MD, MSc, PhD Foothills Medical Centre Calgary, Alberta, Canada Elizabeth Dauer, MD Temple University Philadelphia, PA, USA Jennifer Knight, MD; Nicole Cornell, BS, MS West Virginia University Hospitals Morgantown, WV, USA Forrest “Dell” Moore, MD John Peter Smith Hospital Fort Worth, TX, USA Matthew Bloom, MD Cedars Sinai Hospital Los Angeles, CA, USA Nam T. Tran, MD; Eileen Bulger, MD University of Washington – Harborview Seattle, WA, USA Jeannette G. Ward, MS-CR Chandler Regional Medical Center Chandler, AZ, USA John K. Bini, MD; John Matsuura, MD; Joshua Pringle, MD; Karen Herzing, BSN, RN; Kailey Nolan, BS Wright State Research Institute - Miami Valley Hospital Dayton, OH, USA Nathaniel Poulin, MD; Vidant Medical Center Greeneville, NC, USA William Teeter, MD University of North Carolina at Chapel Hill Chapel Hill, NC, USA Rachel Nygaard, PhD; Chad Richardson, MD; Joseph Skaja, MD; Derek Lombard, MD Hennepin Healthcare Minneapolis, MN, USA Reagan Bollig, MD; Brian Daley, MD; Niki Rasnake, BSN, RN, CEN University of Tennessee Medical Center Knoxville, TN, USA Marko Bukur, MD; Elizabeth Warnack, MD Bellevue Hospital /NYU New York, NY, USA Joseph Farhat, MD North Memorial Medical Center Minneapolis, MN, USA Robert M. Madayag, MD, FACS; Pamela Bourg, PhD, RN, TCRN, FAEN St. Anthony Hospital Lakewood, CO, USA.

    • Contributors All authors have made substantial contributions to this article, including conception and design of the study (MAV, RPD, JD, JWC), acquisition and analysis/interpretation of the data (MAV, RPD, JD, JM, TS, LM, JP, KI, AP, DSK, VLB, CS, CF, EEM, JWC), drafting of the article (MAV, RPD, JWC), and critical revisions (MAV, RPD, JD, JM, TS, LM, JP, KI, AP, DSK, VLB, CS, CF, EEM, JWC). All authors have reviewed and approved this final article.

    • Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.

    • Competing interests The following conflicts of interest pertain to Prytime Medical Devices: University of Pennsylvania Simulation Center (REBOA simulation equipment); EEM (research support); JM (clinical advisory board); CF (medical consultant); and CS (unpaid speaker).

    • Patient consent for publication Not required.

    • Ethics approval This project was approved by the University of Pennsylvania Institutional Review Board and by each institutional review board at participating sites.

    • Provenance and peer review Not commissioned; externally peer reviewed.

    • Data availability statement All data relevant to the study are included in the article.