Skip to main content

Advertisement

Log in

Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures

  • Published:
Surgical Endoscopy Aims and scope Submit manuscript

Abstract

Background: The use of the Veress needle in laparoscopy to create the pneumoperitoneum has inherent risks; it may cause vascular and visceral injuries. The open technique is compromised by the leakage of carbon dioxide and can also be time consuming. One alternative is to enter the abdomen using an optical trocar under direct view. Our aim was to determine whether the optical access trocar can be used to effect a safe and rapid entry in various laparoscopic procedures. Methods: Over a 4-year period, the Optiview trocar was used for initial entry in 650 laparoscopic procedures. The procedures included cholecystectomy (n = 282), transabdominal inguinal hernia repair (n = 76), radiofrequency ablation of liver tumors (n = 73), adrenalectomy (n = 54), appendectomy (n = 41), colorectal surgery (n = 39), and various other procedures (n = 85). The following parameters were analyzed: presence of previous abdominal operations, site and duration of entry, and complications. Results: Of the 650 patients, 156 (24%) had had previous abdominal operations. In 25 cases, previous trocar sites were reused for optical access. The optical trocar was inserted at the umbilicus in 495 patients (76%), in the right upper quadrant in 77 (12%), in the left upper quadrant in 26 (4%), in the upper midline in eight (1%), in the right lower quadrant in six (0.9%), and in the left lower quadrant in three (0.5%). In 35 patients undergoing posterior adrenalectomy, optical trocars were used to enter Gerota's space. Mean (SD) entry times were 92 (45) sec at the umbilical site, 114 (30) sec at the back, and 77 (35) sec at the remaining sites. Complications (0.3%) included one injury to the bowel and one injury to the gallbladder; however, they were recognized and repaired immediately. Conclusions: To our knowledge, this report comprises the largest series in which the optical access trocar was used for laparoscopic surgery. This device provides the basis for a safe and fast technique for initial trocar placement: it also has the potential to reduce costs. Thanks to our favorable experience, the optical trocar method has become the standard technique for abdominal access in our laparoscopic practice since 1995.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

apd: 3 April 2001

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

String, A., Berber, E., Foroutani, A. et al. Use of the optical access trocar for safe and rapid entry in various laparoscopic procedures. Surg Endosc 15, 570–573 (2001). https://doi.org/10.1007/s004640080056

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004640080056

Navigation