Abstract

Purpose

To evaluate the diagnostic accuracy of ultrasonography of optic nerve sheath diameter (ONSD) for assessment of intracranial hypertension.

Methods

Systematic review without language restriction based on electronic databases, with manual review of literature and conference proceedings until July 2010. Studies were eligible if they compared ultrasonography of ONSD with intracranial pressure (ICP) monitoring. Data were extracted independently by three authors. Random-effects meta-analysis and meta-regression were performed.

Results

Six studies including 231 patients were reviewed. No significant heterogeneity was detected for sensitivity, specificity, positive and negative likelihood ratios or diagnostic odds ratio. For detection of raised intracranial pressure, pooled sensitivity was 0.90 [95% confidence interval (CI) 0.80–0.95; p for heterogeneity, p het = 0.09], pooled specificity was 0.85 (95% CI 0.73–0.93, p het = 0.13), and the pooled diagnostic odds ratio was 51 (95% CI 22–121). The area under the summary receiver-operating characteristic (SROC) curve was 0.94 (95% CI 0.91–0.96).

Conclusions

Ultrasonography of ONSD shows a good level of diagnostic accuracy for detecting intracranial hypertension. In clinical decision-making, this technique may help physicians decide to transfer patients to specialized centers or to place an invasive device when specific recommendations for this placement do not exist.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Guillaume J, Janny P (1951) Continuous intracranial manometry; physiopathologic and clinical significance of the method. Presse Med 59:953–955

    PubMed  CAS  Google Scholar 

  2. Lundberg N (1960) Continuous recording and control of ventricular fluid pressure in neurosurgical practice. Acta Psychiatr Scand Suppl 36:1–193

    PubMed  CAS  Google Scholar 

  3. Rickert K, Sinson G (2003) Intracranial pressure monitoring. Oper Tech Gen Surg 5:170–175

    Article  Google Scholar 

  4. The brain trauma foundation. The american association of neurological surgeons. The joint section on neurotrauma, critical care (2000) Recommendations for intracranial pressure monitoring technology. J Neurotrauma 17:497–506

    Article  Google Scholar 

  5. Wilberger JE Jr (1997) Outcomes analysis: intracranial pressure monitoring. Clin Neurosurg 44:439–448

    PubMed  Google Scholar 

  6. Paramore CG, Turner DA (1994) Relative risks of ventriculostomy infection and morbidity. Acta Neurochir (Wien) 127:79–84

    Article  CAS  Google Scholar 

  7. Winkler F, Kastenbauer S, Yousry TA, Maerz U, Pfister HW (2002) Discrepancies between brain CT imaging and severely raised intracranial pressure proven by ventriculostomy in adults with pneumococcal meningitis. J Neurol 249:1292–1297

    Article  PubMed  Google Scholar 

  8. Hiler M, Czosnyka M, Hutchinson P, Balestreri M, Smielewski P, Matta B, Pickard JD (2006) Predictive value of initial computerized tomography scan, intracranial pressure, and state of autoregulation in patients with traumatic brain injury. J Neurosurg 104:731–737

    Article  PubMed  Google Scholar 

  9. Hassler W, Steinmetz H, Gawlowski J (1988) Transcranial doppler ultrasonography in raised intracranial pressure and in intracranial circulatory arrest. J Neurosurg 68:745–751

    PubMed  CAS  Google Scholar 

  10. Schmidt B, Czosnyka M, Raabe A, Yahya H, Schwarze JJ, Sackerer D, Sander D, Klingelhofer J (2003) Adaptive noninvasive assessment of intracranial pressure and cerebral autoregulation. Stroke 34:84–89

    Article  PubMed  Google Scholar 

  11. Aaslid R, Huber P, Nornes H (1986) A transcranial doppler method in the evaluation of cerebrovascular spasm. Neuroradiology 28:11–16

    Article  PubMed  CAS  Google Scholar 

  12. Durham B (1996) Emergency medicine physicians saving time with ultrasound. Am J Emerg Med 14:309–313

    Article  PubMed  CAS  Google Scholar 

  13. Antonelli M, Azoulay E, Bonten M, Chastre J, Citerio G, Conti G, De Backer D, Lemaire F, Gerlach H, Groeneveld J, Hedenstierna G, Macrae D, Mancebo J, Maggiore SM, Mebazaa A, Metnitz P, Pugin J, Wernerman J, Zhang H (2009) Year in review in intensive care medicine, 2008: I. Brain injury and neurology, renal failure and endocrinology, metabolism and nutrition, sepsis, infections and pneumonia. Intensive Care Med 35:30–44

    Article  PubMed  Google Scholar 

  14. Galetta S, Byrne SF, Smith JL (1989) Echographic correlation of optic nerve sheath size and cerebrospinal fluid pressure. J Clin Neuroophthalmol 9:79–82

    PubMed  CAS  Google Scholar 

  15. Hansen HC, Helmke K (1997) Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg 87:34–40

    Article  PubMed  CAS  Google Scholar 

  16. Hansen HC, Helmke K (1996) The subarachnoid space surrounding the optic nerves. An ultrasound study of the optic nerve sheath. Surg Radiol Anat 18:323–328

    Article  PubMed  CAS  Google Scholar 

  17. Blaivas M, Theodoro D, Sierzenski PR (2003) Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath. Acad Emerg Med 10:376–381

    Article  PubMed  Google Scholar 

  18. Helmke K, Hansen HC (1996) Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension ii. Patient study. Pediatr Radiol 26:706–710

    Article  PubMed  CAS  Google Scholar 

  19. Helmke K, Hansen HC (1996) Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study. Pediatr Radiol 26:701–705

    Article  PubMed  CAS  Google Scholar 

  20. Kassai B, Sonie S, Shah NR, Boissel JP (2006) Literature search parameters marginally improved the pooled estimate accuracy for ultrasound in detecting deep venous thrombosis. J Clin Epidemiol 59:710–714

    Article  PubMed  Google Scholar 

  21. Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J (2003) The development of quadas: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 3:25

    Article  PubMed  Google Scholar 

  22. Glas AS, Lijmer JG, Prins MH, Bonsel GJ, Bossuyt PM (2003) The diagnostic odds ratio: a single indicator of test performance. J Clin Epidemiol 56:1129–1135

    Article  PubMed  Google Scholar 

  23. Littenberg B, Moses LE (1993) Estimating diagnostic accuracy from multiple conflicting reports: a new meta-analytic method. Med Decis Making 13:313–321

    Article  PubMed  CAS  Google Scholar 

  24. Fleiss J (1981) Statistical methods for rates and proportions, 2nd edn. Wiley, New York

    Google Scholar 

  25. Higgins JP, Thompson SG (2002) Quantifying heterogeneity in a meta-analysis. Stat Med 21:1539–1558

    Article  PubMed  Google Scholar 

  26. Reitsma JB, Glas AS, Rutjes AW, Scholten RJ, Bossuyt PM, Zwinderman AH (2005) Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviews. J Clin Epidemiol 58:982–990

    Article  PubMed  Google Scholar 

  27. Swets JA (1988) Measuring the accuracy of diagnostic systems. Science 240:1285–1293

    Article  PubMed  CAS  Google Scholar 

  28. Egger M, Davey Smith G, Schneider M, Minder C (1997) Bias in meta-analysis detected by a simple, graphical test. BMJ 315:629–634

    PubMed  CAS  Google Scholar 

  29. Deeks JJ, Macaskill P, Irwig L (2005) The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol 58:882–893

    Article  PubMed  Google Scholar 

  30. Baker WL, White CM, Cappelleri JC, Kluger J, Coleman CI (2009) Understanding heterogeneity in meta-analysis: the role of meta-regression. Int J Clin Pract 63:1426–1434

    Article  PubMed  CAS  Google Scholar 

  31. Zamora J, Abraira V, Muriel A, Khan K, Coomarasamy A (2006) Meta-disc: a software for meta-analysis of test accuracy data. BMC Med Res Methodol 6:31

    Article  PubMed  Google Scholar 

  32. Beare NA, Kampondeni S, Glover SJ, Molyneux E, Taylor TE, Harding SP, Molyneux ME (2008) Detection of raised intracranial pressure by ultrasound measurement of optic nerve sheath diameter in African children. Trop Med Int Health 13:1400–1404

    Article  PubMed  Google Scholar 

  33. Brzezinska R, Schumacher R (2002) Diagnosis of elevated intracranial pressure in children with shunt under special consideration of transglobe sonography of the optic nerve. Ultraschall Med 23:325–332

    Article  PubMed  CAS  Google Scholar 

  34. Fagenholz PJ, Gutman JA, Murray AF, Noble VE, Camargo CA Jr, Harris NS (2009) Optic nerve sheath diameter correlates with the presence and severity of acute mountain sickness: evidence for increased intracranial pressure. J Appl Physiol 106:1207–1211

    Article  PubMed  Google Scholar 

  35. Girisgin AS, Kalkan E, Kocak S, Cander B, Gul M, Semiz M (2007) The role of optic nerve ultrasonography in the diagnosis of elevated intracranial pressure. Emerg Med J 24:251–254

    Article  PubMed  Google Scholar 

  36. Goel RS, Goyal NK, Dharap SB, Kumar M, Gore MA (2008) Utility of optic nerve ultrasonography in head injury. Injury 39:519–524

    Article  PubMed  Google Scholar 

  37. Korber F, Scharf M, Moritz J, Dralle D, Alzen G (2005) Sonography of the optical nerve experience in 483 children. Rofo 177:229–235

    PubMed  CAS  Google Scholar 

  38. Malayeri AA, Bavarian S, Mehdizadeh M (2005) Sonographic evaluation of optic nerve diameter in children with raised intracranial pressure. J Ultrasound Med 24:143–147

    PubMed  Google Scholar 

  39. McAuley D, Paterson A, Sweeney L (2009) Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus. Childs Nerv Syst 25:87–90

    Article  PubMed  Google Scholar 

  40. Newman WD, Hollman AS, Dutton GN, Carachi R (2002) Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus. Br J Ophthalmol 86:1109–1113

    Article  PubMed  CAS  Google Scholar 

  41. Salgarello T, Tamburrelli C, Falsini B, Giudiceandrea A, Colotto A (1996) Optic nerve diameters and perimetric thresholds in idiopathic intracranial hypertension. Br J Ophthalmol 80:509–514

    Article  PubMed  CAS  Google Scholar 

  42. Shuper A, Snir M, Barash D, Yassur Y, Mimouni M (1997) Ultrasonography of the optic nerves: clinical application in children with pseudotumor cerebri. J Pediatr 131:734–740

    Article  PubMed  CAS  Google Scholar 

  43. Tayal VS, Neulander M, Norton HJ, Foster T, Saunders T, Blaivas M (2007) Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients. Ann Emerg Med 49:508–514

    Article  PubMed  Google Scholar 

  44. Tsung JW, Blaivas M, Cooper A, Levick NR (2005) A rapid noninvasive method of detecting elevated intracranial pressure using bedside ocular ultrasound: application to 3 cases of head trauma in the pediatric emergency department. Pediatr Emerg Care 21:94–98

    Article  PubMed  Google Scholar 

  45. Sutherland AI, Morris DS, Owen CG, Bron AJ, Roach RC (2008) Optic nerve sheath diameter, intracranial pressure and acute mountain sickness on mount everest: a longitudinal cohort study. Br J Sports Med 42:183–188

    Article  PubMed  CAS  Google Scholar 

  46. Watanabe A, Kinouchi H, Horikoshi T, Uchida M, Ishigame K (2008) Effect of intracranial pressure on the diameter of the optic nerve sheath. J Neurosurg 109:255–258

    Article  PubMed  Google Scholar 

  47. Le A, Hoehn ME, Smith ME, Spentzas T, Schlappy D, Pershad J (2009) Bedside sonographic measurement of optic nerve sheath diameter as a predictor of increased intracranial pressure in children. Ann Emerg Med 53:785–791

    Article  PubMed  Google Scholar 

  48. Geeraerts T, Launey Y, Martin L, Pottecher J, Vigue B, Duranteau J, Benhamou D (2007) Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury. Intensive Care Med 33:1704–1711

    Article  PubMed  Google Scholar 

  49. Geeraerts T, Merceron S, Benhamou D, Vigue B, Duranteau J (2008) Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med 34:2062–2067

    Article  PubMed  Google Scholar 

  50. Kimberly HH, Shah S, Marill K, Noble V (2008) Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med 15:201–204

    Article  PubMed  Google Scholar 

  51. Moretti R, Pizzi B (2009) Optic nerve ultrasound for detection of intracranial hypertension in intracranial hemorrhage patients: confirmation of previous findings in a different patient population. J Neurosurg Anesthesiol 21:16–20

    Article  PubMed  Google Scholar 

  52. Moretti R, Pizzi B, Cassini F, Vivaldi N (2009) Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage. Neurocrit Care 11:406–410

    Article  PubMed  Google Scholar 

  53. Soldatos T, Karakitsos D, Chatzimichail K, Papathanasiou M, Gouliamos A, Karabinis A (2008) Optic nerve sonography in the diagnostic evaluation of adult brain injury. Crit Care 12:R67

    Article  PubMed  Google Scholar 

  54. Bratton SL, Chestnut RM, Ghajar J, McConnell Hammond FF, Harris OA, Hartl R, Manley GT, Nemecek A, Newell DW, Rosenthal G, Schouten J, Shutter L, Timmons SD, Ullman JS, Videtta W, Wilberger JE, Wright DW (2007) Guidelines for the management of severe traumatic brain injury. Vi. Indications for intracranial pressure monitoring. J Neurotrauma 24 Suppl 1:S37–S44

    PubMed  Google Scholar 

  55. Fagan TJ (1975) Letter: nomogram for bayes theorem. N Engl J Med 293:257

    PubMed  CAS  Google Scholar 

  56. Bauerle J, Lochner P, Kaps M, Nedelmann M (2010) Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults. J Neuroimaging (epub ahead of print)

  57. Patel HC, Bouamra O, Woodford M, King AT, Yates DW, Lecky FE (2005) Trends in head injury outcome from 1989 to 2003 and the effect of neurosurgical care: an observational study. Lancet 366:1538–1544

    Article  PubMed  CAS  Google Scholar 

  58. MacKenzie EJ, Rivara FP, Jurkovich GJ, Nathens AB, Frey KP, Egleston BL, Salkever DS, Scharfstein DO (2006) A national evaluation of the effect of trauma-center care on mortality. N Engl J Med 354:366–378

    Article  PubMed  CAS  Google Scholar 

  59. Thornton A, Lee P (2000) Publication bias in meta-analysis: its causes and consequences. J Clin Epidemiol 53:207–216

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Julie Dubourg.

Additional information

This article is discussed in the editorial available at: doi:10.1007/s00134-011-2226-0.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dubourg, J., Javouhey, E., Geeraerts, T. et al. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med 37, 1059–1068 (2011). https://doi.org/10.1007/s00134-011-2224-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00134-011-2224-2

Keywords

Navigation